TY-9000 Full Digital Direct Reading Spectrometer|High Precision Metal Alloy Element Analyzer|Ultra-Low Detection Limit Industrial Spectrometer

Optical Emission Spectrometers TY-9000-1.png
Optical Emission Spectrometers TY-9000-2
Optical Emission Spectrometers TY-9000-1
Specific Information
Please contact us

Refunds

Contact us for details

Payment method

COMM
COMM
Product Details
Product Introduction
LaiZhou JinCheng Industrial Equipment Co., Ltd. presents the TY-9000 Full Digital Optical Emission Spectrometer — a high-performance solution engineered for precision elemental analysis in metallurgy. Designed for iron, aluminum, copper, and other alloy systems, this spectrometer offers ppm-level detection limits across a 165–589 nm wavelength range using vacuum optics and CCD detector technology. Certified to ASTM and ISO standards, it ensures reliable results with error margins under 0.5%, making it ideal for foundries, machining plants, and R&D labs worldwide. The TY-9000 supports rapid alloy identification, enhances production consistency, and meets global compliance requirements — all backed by professional installation, calibration, and technical support services tailored for B2B international clients.
Advantages and features
1. Achieves ultra-low detection limits down to ppm levels for precise alloy composition verification.2. Vacuum chamber and CCD detector ensure stable performance and long-term reliability.3. Complies with ASTM E1475 and ISO 17025 standards for international quality assurance.4. Fast analysis time with minimal sample preparation—ideal for high-throughput environments.5. User-friendly interface and remote diagnostics simplify operation and maintenance for global users.
Application Scenario
Ideal for metallurgical industries including foundries, steel mills, aluminum casting facilities, mechanical processing plants, and research institutions that require accurate, fast, and compliant elemental analysis of ferrous and non-ferrous alloys. Suitable for customers in North America, Europe, Asia, and emerging markets seeking advanced analytical solutions for quality control and process optimization.
Product Parameters

Scope of supply

No.

Item

Specifications

QTY

Unit

Remarks

1

Optical Emission Spectrometer

TY-9000

1

Set

Include in quotation.

2

Business computer

 

1

Set

3

Printer

 

1

Set

4

Tungsten electrode

 

1

Pc

5

Electrode pressure spring

 

1

Pc

6

The electrode fixed screw

 

2

Pcs

7

Electrode brush

Φ6

2

Pcs

8

Lens holder sealing ring

Φ16×2.65

2

Pcs

9

Spark stand sealing ring

Φ72×2.65

1

Pc

10

Exhaust gas filter core

 

1

Pc

11

Degreasing cotton

 

15

G

12

Power socket

 

1

Pc

13

M2 Internal hexagonal wrench

 

1

Set

14

M4 Internal hexagonal wrench

 

1

Set

15

Long handle phillips screwdriver

 

1

Pc

16

13-15 fixed wrench

 

1

Pc

17

Spark stand screw

M6

4

Pcs

18

Fuse

10A

2

Pcs

19

Argon gas pressure reducing valve

 

1

Pc

20

Argon gas pipeline

 

2

M

21

Exhaust pipe

 

1

Pc

22

Gas bottle

 

2

Pcs

23

Print paper

 

1

Pc

24

Spectrometer manual

 

1

Set

Technical Data of TY-9000

Item

Index

 

 

 

 

 

Optical System

Focal Length

400mm

Wavelength range

165~589nm (Extendable)

Detector

High resolution CCD Multi detectors

Degree of vacuum

Auto control within 6-20 pa

Pixel resolution

30pm

Grating line

2400m1/mm

First order spectral line dispersion rare

1.2nm/mm

Average resolution ratio

10pm/pixel

Full spectrum

Light room temperature is controlled automatically

 

 

 

 

Spark Source

Type

Digital arc and spark source

Spark frequency

100-1000HZ

Discharge current

1-400A

Ignition voltage

>15000V

 

Excitation light

Optimization of discharge parameters design

High energy precombustion technology HEPS

 

Processor

High-speed data synchronization acquisition and processing

 

 

Spark Stand

Electrode

Tungsten electrode technology

Make up

Thermal deformation self-compensation design

Argon flushed with minimal consumption of Argon

Spray discharge electrode technology

Adjustable electrode technology

 

 

 

 

Others

Measurable elements

Fe、Al、Cu、Ni、Ti、Co、Zn、Sn、Mg、Pb  etc

Dimension

800mm(L)*700mm*470mm(H)

weight

About 100kg

Storage temperature

0℃-45℃

Operating temperature

10℃-35℃, 23±2℃ is recommended

Power

AC220V/50Hz(Customized)

Power consumption

Excitation:700W/Stand by:100W

Argon quality

99.999%, Argon pressure>4Mpa

Argon consumption

5L/min during spark mode

Interface

Ethernet data transmission based on DM9000A

Type Qty Note
High purity argon gas (pure ≧ 99.999%) 1 bottle Should prepare by customer. If can’t get should use argon purifier to get 99.999% argon gas.
Small air conditioning 1 set Essential, customer should prepare by themselves.
High precision magnetic saturation voltage stabilizer (1KVA) 1 set Need for voltage instability, if the customer uses intermediate frequency furnace, then need 3KVA Voltage Stabilizer
Argon purifier 1 set When argon gas is not as pure as 99.999%.
Samples grinder (ferrous metals) or Mini lathe (non-ferrous metals) 1 set Essential
Type samples pieces Essential for foundry
Contact us
Contact us
https://shmuker.oss-accelerate.aliyuncs.com/tmp/temporary/60ec5bd7f8d5a86c84ef79f2/60ec5bdcf8d5a86c84ef7a9a/thumb-prev.png